Section 7: Datalogger Management Centre (DLMC)

                3.7.1  At Divn. HQ.

                        (a) Data  Logger  Management  Centre  generally  situated  at  Divisional
                            Headquarters shall be extensively used for monitoring of signalling system
                            in the entire division.  SSE/JE(Signal)(HQ) shall continuously or regularly
                            monitor  Data  Logger  exception  reports  and  inform  concerned
                            SSE(Signal)/Incharge, Sectional SSE/JE(Signal) for necessary action.

                        (b) When  a  new  station  is  commissioned  or  alterations  are  carried  out  in
                            existing station, SSE(Signal)/Incharge shall ensure that all specified relays
                            and  gears  are  monitored  by  Datalogger  at  the  station  ensure  its  proper
                            validation.

                        (c) SSE(Signal)/Incharge/DLMC  shall  ensure  that  SMS  alerts  are  generated
                            for Safety related faults & Maintenance related faults.

                        (d) SSE/JE(Signal)/DLMC  shall  ensure  monitoring  of  Relay  Room  door
                            opening,  fire  alarm,  Power  supply/Battery  voltages,  ELD  and  other
                            specified gears through SMS alert generated by Data logger.

                        (e) SSE/JE(Signal)/DLMC  at  divisional HQ  shall  ensure data  availability  and
                            network connectivity continuously to zonal HQ/Railway Board.

                        (f)  SSE/JE(Signal)/DLMC at divisional HQ  shall ensure Prompt and regular
                            validation  of  Datalogger  inputs  in  coordination  with  SSE(Signal)/Incharge
                            of the Station/IB/LC.

                                        Section 8: Duties of Technician(Signal)


                3.8.1  Duties of Technician (Signal)
                        The  duties  of    Technician(Signal)  are  detailed  in  various  Chapters  in  this
                        Manual, the most essential being:

                        (a) Efficient maintenance and testing of all equipments under his charge such
                            as Mechanical Signalling equipments, Electrical and Electronic Signalling
                            equipments,  Telecommunication  equipments  etc.  so  as  to  keep  them
                            properly  maintained  and  in  good  working  condition,  in  accordance  with
                            instructions contained in this manual and such circulars or instructions, as
                            may be issued from time to time.
                            Note:  The  term  Electrical/Electronic  Signalling  equipments  includes  all  types  of
                            Block Instruments also.

                        (b) Carrying  out  works  and  alterations  to  the  existing  installations  under  the
                            instructions of the SSE/JE (Signal) or S&T officers.

                        (c) Responding  promptly  to  messages  received  through  Datalogger  or  Test
                            Room or Station Staff.
                        (d) Bringing to the notice of the SSE/JE (Signal) any emergency and situation
                            that may be beyond his competence or control by a message on control or
                            phone or other means of communication.



                                       Chapter 3: Duties Of Signal Supervisors And Technical Staff   Page 24 of 535