Page 597 - IRSEM_Main Book
P. 597

S No   Term   Description/Meaning in SEM       Relevant paras
 After application of this type of resetting, axle counter will continue to show ‘Occupied’ until  17.7.4(a), 17.7.5 (b)
 Reset –
 122   one train movement is carried out through the failed section and ‘In Count’ is matched with
 Preparatory
 ‘Out Count’.
                                                Annexure: 18-A4 II
 Supervisory   A section of track between two Detection Points completely covering more than one track  (B),(D),
 123  Track Section   section and is used to automatically reset failed Track sections under its jurisdiction, when it
                                                Annexure:21-A1 (C),
 & Reset   is safe to do so without manual intervention. This is also called Auto-Reset.
                                                (D)

                                                17.5.6 (c), 19.8.12 (f),
 124  Risk   Combination of expected frequency of loss and the expected degree of severity of that loss.
                                                21.1.11(c)
                                                7.1.14(c),7.4.5,
 Means the line governed by one or more signals and includes connections, if any, used by a
                                                7.4.6(a),7.4.12,
 125  Running Line   train  when  entering  or  leaving  a  station  or  when  passing  through  a  station  or  between
                                                12.5.6(d), 12.26.3(a)
 stations.
                                                Annexure: 7-A1
 Means a train, which has started under an authority to proceed and has not completed its  15.2.2(e),
 126  Running Train
 journey.                                       Annexure: 7-A1
 It  is  a  Rail  which  has  developed  rust  formation  on  its  surface  and  does  not  cause  De- 17.3.13
 127  Rusty Rail   Energisation of Track relay as required, when a Train/Light Engine/Motor Trolley is occupying
 it, thus causing an unsafe side failure.
                                                9.1.1(a), 9.2.1,  9.2.4,
 128  Safety   Freedom from unacceptable risk.
                                                9.2.5
 Safety   Positive declaration intended to give confidence that Risk Process and behaviors are being  Annexure: G1(2.2)
 129
 Assurance   managed to acceptable levels through appropriate measures.
 Documented  demonstration  that  the  product  (eg.  a  system,  subsystem  or  equipment)
 130  Safety Case
 complies with the specified safety requirements.
 Safety                                         21.4.5(b),
 131   Function whose sole purpose is to ensure safety.
 Function                                       Annexure: G1(4.4)
 132  Safety   Ability of a safety related system to achieve its required safety functions under all the stated  13.1.3(c), 21.4.1(b),
 Integrity   conditions within a stated operational environment and within a stated duration.   Annexure: G1(4.8)


 Annexure: G4: Glossary of Technical Terms for Signal Engineering Manual   Page 526 of 535
   592   593   594   595   596   597   598   599   600   601   602