Page 26 - IRSEM_Main Book
P. 26

(d) Each  Sectional  SSE/JE  (Signal)  may  be  provided  with  trolley/motor
                            trolley/utility vehicle. Where trolley is provided adequate number of trolley
                            men/Helpers shall also be provided.

                        (e) Each Sectional SSE/JE (Signal) shall be assisted by appropriate staff as
                            provided for a SSE (Signal)/Incharge.

                1.3.5  Strength of staff

                        (a) The  strength  of  SSE/JE,  Signal  Technicians,  Sectional  gangs  and  office
                            staff shall be generally in accordance with an approved yard stick of the
                            Railway Board.

                        (b) Where  such  a  yard  stick  is  not  available,  the  Principal  Chief  Signal  and
                            Telecommunication  Engineer  shall  frame  a  suitable  one  with  due
                            consideration  to  the  standard  of  signalling,  type  of  installation,  size  of
                            yards, density of train services and general importance of the section.

                1.3.6  Drawing Office Organisation

                        (a) Senior Section Engineer (Design and Drawing): SSE(D&D)

                        (b) Junior Engineer (Design and Drawing): JE(D&D)

                1.3.7  Responsibility of drawing Office

                        (a)  Drawing and design office of Zonal Railway for open line & Construction
                            organisation  is  generally  situated  at  Zonal  HQ.  This  will  be  handled  by
                            JAG/SG  officer  who  may  be  assisted  by  Sr.  Scale/Jr.  Scale  officers  &
                            SSE's/JEs D&D.

                        (b)  This office is primarily responsible for preparation and checking of various
                            designs and documents such as Signal Interlocking Plan, Control Table,
                            Panel/VDU Diagram, Wiring Diagrams, Application logic Circuits, Interface
                            circuits, Installation drawings, Earthing diagrams etc., as per latest policies
                            and guidelines of Railway Board and Zonal Railway HQ office.

                        (c) Organisation for Design and Drawing with Division and other field units of
                            Construction, Project etc. shall be manned by JE/SSE (Signal) who will be
                            designated as JE/SSE (D&D).

                        (d) A similar but smaller drawing office may be established in field units viz.,
                            Sr.DSTE/Dy.CSTE’s  for  their  needs,  such  as  Location  drawings,  Cable
                            Layout  Plan,  Cable  Core  distribution  Plan,  Track  Circuit  Bonding  Plans,
                            Traction Bonding Plan etc.

                1.3.8   Other Staff
                        (a) Signal Technician/Signal Maintainer (SM)/Technician(Signal)

                        (b) Assistant (S&T) or Helper











                                    Chapter 1: Organisation Of The Signal & Telecommunication Department   Page 6 of 535
   21   22   23   24   25   26   27   28   29   30   31