Page 63 - IRSEM_Main Book
P. 63
Para no: 3.1.1(a) Annexure: 3-A5
List of Drawings & Registers at a Station
Name of the station: ………………………….….., Section: …………………..………. Division: ..………………...
S.No Drawings to be Maintained at a Station - Table 1 Yes/No/NA
1 Signal Interlocking plan of station (SIP)
2 Table of Controls (TOC)/Selection Table/Route Control Charts
Approved Relay/E.I Room Wiring Circuits (with Contact Analysis
3
updated)
4 Approved EI Logic circuits
5 Approved E I Interface circuits
6 Relay Racks layout & Relay Disposition Plan
7 Cable Termination details in Relay Room
8 Power Supply Distribution/Wiring Diagram
9 Power Equipment Layout
10 Track Circuit bonding diagram
11 Traction Bonding Diagram
12 Cable Route plan
13 Cable core/distribution plan
14 Location Termination particulars
15 Signal Sighting committee Reports
16 Station Working Rules (SWR) & SWOD
17 Safety Certificate
18 EI Checksum certificate
19 Any other as per requirements
S.No Registers to be Maintained at a Station - Table 2 Yes/No/NA
1 Signal Failure Register
2 Control Panel/Control Terminal Maintenance Register
3 Emergency Route/Sub route Cancellation Register
4 Emergency Point Operation/Crank Handle Extraction Register
5 Axle Counter/MSDAC Reset Registers
6 Cabin/Relay Room Key Register
7 Disconnection/Reconnection Register
8 Signal maintenance Register
9 Signal Equipment History book
10 Station Signalling Asset Register
Chapter 3: Duties Of Signal Supervisors And Technical Staff Page 41 of 535