Page 420 - IRSEM_Main Book
P. 420

(e) Extracting of/replenishment of tokens in Token instruments shall be done
                            when the instruments are in the "Line Closed" position.

                        (f)  Token pouches shall be kept in proper repair by the Traffic Department and
                            damaged pouches shall not be allowed to be used.


                            Note: Also refer to para No. 18.9.1.

               18.7.6  Responsibility of the Operating Staff

                        (a) Staff  operating  the  instruments  is  responsible  for  the  safe  working  of  the
                            instruments,  which  is  dependent  on  the  correct  use  of  the  code  of  bell
                            signals  and  the  correct  operation  of  the  instruments  being  carried  out  in
                            proper sequence.

                        (b) Importance  of  Bell  Signals:  The  provision  of  telephones  does  not  do
                            away with the necessity for use of authorised code of bell signals.


                         Section 8: Maintenance of Block Instruments & their Ancillary
                                            Apparatus - General Instructions

               18.8.1  (a) Technician shall ensure by a fortnightly check that

                        (b) Locks: Electrical or Mechanical Locks are in a condition that they are not
                            liable to be forced.

                        (c) Indicators:  Indicators  operate  fully  and  return  to  the  normal  position
                            correctly when released.

                        (d) Contacts: All contacts are clean and free from pitting, if surfaces are pitted,
                            they shall be cleaned with chamois leather and refurbished.

                        (e) All springs are in good condition and kept properly adjusted.

                        (f)  Relay  Armatures:  Relay  armatures  are  free  and  return  to  their  normal
                            position when no current is flowing.


                        (g) Track  Circuits: Instructions as laid  down  in Chapter 17 of SEM shall be
                            adhered to.

                        (h) External Wiring: All wiring is in good condition and free from joints. Joints,
                            wherever necessary, are properly soldered and insulated.

                        (i)  Terminal  Screws:  All  terminal  screws,  lock  nuts  and  locking  screws  are
                            kept tight and split pins opened.

                        (j)  Batteries: All batteries are kept clean, terminals tight and free from dirt or
                            corrosion and maintained in accordance with instructions in Chapter 16 of
                            SEM.

                        (k) Lightning  Protector:  Lightning  and  power  protective  devices  and  earth
                            connections are effective and in good condition.




                                          Chapter 18: Block Instruments, BPAC & IBS Working       Page 368 of 535