Page 36 - IRSEM_Main Book
P. 36

(e) In Token Block Working Territory, a suitable light is displayed at the token
                            delivery  and  pickup  area  for  the  Loco  Pilot  to  clearly  drop  the  incoming
                            token and pick up the outgoing token.

                        (f)  All Warning Boards and other boards maintained by Signal department are
                            in good condition.


                3.1.4  Attending to Failures/Incidences

                        (a) The Sectional SSE/JE(Signal) shall monitor daily all failures on his section.
                            During his periodical inspection he shall check up the cause indicated as
                            well as repairs carried out to ensure that similar faults do not recur. In case
                            of  failures  of  a  serious  nature,  the  investigation  shall  be  carried  out
                            immediately, and the SSE(Signal)/Incharge advised.

                        (b) Each  Sectional  SSE/JE(Signal),  shall  at  the  end  of  every  month,
                            summarise the failure reports received from each Technician(Signal) and
                            submit  monthly  ‘Cause  wise  Analysis  Of  Signal  Incidences’  as  per
                            Annexure:  3-A6  with  his  remarks  to  the  Sr.  Divisional  Signal  and
                            Telecommunication  Engineer  in  duplicate.  Failures  pertaining  to  other
                            departments  shall  be  promptly  brought  to  the  notice  of  the  concerned
                            departments.

                        (c) SSE(Signal)/Incharge, Sectional SSE/JE(Signal) shall monitor Datalogger
                            exception  reports  on  daily  basis  and  take  corrective  actions.  Where
                            required, he shall take assistance from Data Logger Management Centre
                            (DLMC) in Divisional headquarters.

                3.1.5  Competency in Rules and Technical Work: Sectional SSE/JE (Signal) shall be:

                        (a) Fully  conversant  with  the  rules  and  regulations,  instructions,  procedures
                            and practices of installation, operation and maintenance of all installations
                            under his charge.

                        (b) Competent to carry out under open line working conditions
                            (i)  Additions and alterations to existing installations and circuits

                            (ii) New installations
                            (iii) Installation,  adjustment,  maintenance  and  testing  of  Relay/Electronic
                               Interlocking equipments, Point Machines, Train Detection devices, LC
                               gates & carrying out alterations whenever required.

                        (c) The  Sectional SSE/JE(Signal)  shall  ensure  that  only  competent  staff  are
                            permitted to work on or make adjustments to any of the signalling gears
                            which are connected with the safety of trains. The supervisors shall further
                            ensure  that  these  instructions  are  clearly  understood  by  all  the  staff
                            concerned.  Wherever  contractual  staff  are  deployed  their  technical
                            competency  and  awareness  on  safety  matters,  shall  be  checked  before
                            they are allowed to work. Contractual staff shall not be allowed to work in
                            Relay Room, Point Mechanisms, Cables or any vital circuits independently,
                            unless accompanied by Railway Staff in a working Installation.




                                       Chapter 3: Duties Of Signal Supervisors And Technical Staff   Page 15 of 535