Page 584 - IRSEM_Main Book
P. 584

S No        Term                                       Description/Meaning in SEM                                    Relevant paras
                                       Limit of the ratio of the conditional probability that the instant of time T, of a failure of a  3.1,3.5 of Annexure: G1
                59    Failure Rate     product falls within a given time interval (t, t+ Δt) and the duration of this interval Δt, when
                                       Δt tends towards zero, given that the items is in an up state
                      Factory          A type of Testing done to check whether Software logics of Interlocking/Equipment, to be  3.6.5(b), 21.5.2(a)
                60    Acceptance       Installed are responding fully in accordance with logics defined in Control Tables. This is done  (b)(d), 13.1.9(c),
                      Test (FAT)       without any Interface wiring in Relay Room and no connection to Outdoor equipments.
                                       Means a signal of fixed location indicating a condition affecting the movement of a train and  12.5.10(a), 13.2.2 (b),
                61    Fixed Signal
                                       includes a semaphore arm or disc or fixed light for use by day and fixed light for use by night.   20.1.2(b), 20.1.3(a)
                                                                                                                                    7.1.14(d), 7.3.6(b),
                                       It marks at which the infringement of two fixed Standard Dimensions fouling block occurs,    7.4.9(b), 7.6.5(b),
                62    Fouling Mark     where two lines cross or join one another. It is placed at a location, where centre to centre
                                                                                                                                    7.6.6(c), 12.5.6,
                                       distance is less than 4265 mm for existing works and 5300 mm for new works.
                                                                                                                                    17.2.4(a)(b)
                      Functional       Part of overall safety that depends on functional and physical units operating correctively in  Annexure: G1(S.No-4.1)
                63
                      Safety           response to their inputs.
                                       Means a train (other than material train) intended solely or mainly for the carriage of animals  Annexure: 13-A1
                64    Goods Train
                                       or goods.
                                                                                                                                    7.1.14(c), 7.5.3, 7.5.6,
                                       Means the railway servant in charge of a train and includes a Brakesman or any other railway
                65    Guard                                                                                                         7.7.2(f), 8.1.9(e),
                                       servant who may for the time being be performing the duties of a Guard.
                                                                                                                                    22.1.1(c)
                66    Hazard           Condition that could lead to an accident.                                                    17.4.2(h), 17.5.4 (e)
                      Hazard           Process of identifying hazards and analysing their causes and the derivation of requirements
                67
                      Analysis         to limit the likelihood and consequences of hazards to a tolerable level.
                                                                                                                                    Annexure: G1
                68    Hazard Rate      Rate of occurrence of hazard.
                                                                                                                                    (3.4, 4.12)
                                       It is an arrangement for the changeover of system from one active unit to another active unit,  13.3.3(b)(d), 21.4.6(a)
                69    Hot Standby
                                       being provided for same purpose.
                                                                                                                                    19.2.1(b),
                70    Implantation     Horizontal distance from centre of the track.
                                                                                                                                    Annexure: 3-A1


                                                         Annexure: G4: Glossary of Technical Terms for Signal Engineering Manual                   Page 520 of 535
   579   580   581   582   583   584   585   586   587   588   589